Answer:
A Run-Time Error is generated in a program when a component
fails. Below is a list of known Runtime Errors in the Ioline 301
program and what they mean.
- Run-time error #5
"Invalid Procedure Call"
Occurs only when the file name you are exporting exceeds 16 characters
(prefix), and trying to export in Tajima format. Other formats
are not affected. To solve this problem rename the file to
something less than 16 characters.
- Run-time error #6
"Overflow"
Occurs when a design is imported and its coordinates are greater than
32,760. This is never a problem with designs appropriate for
embroidery, however designs that originated as signs may cause this
error.
- Run-time Error #57
"Device I/O"
Involves the information being sent to the device. Check all
connections from the cutter to the computer. It may also be
necessary to restart both the computer and the cutter to clear this
error.
- Run-time Error #75
"Path/File Access Error"
File location of path
does not exist. Check the spelling of the filename and path.
|