Question: What is a Run-Time Error?
Answer: A Run-Time Error is generated in a program when a component fails.  Below is a list of known Runtime Errors in the Ioline 301 program and what they mean.
  • Run-time error #5 "Invalid Procedure Call"
    Occurs only when the file name you are exporting exceeds 16 characters (prefix), and trying to export in Tajima format.  Other formats are not affected.  To solve this problem rename the file to something less than 16 characters.
  • Run-time error #6 "Overflow"
    Occurs when a design is imported and its coordinates are greater than 32,760.  This is never a problem with designs appropriate for embroidery, however designs that originated as signs may cause this error. 
  • Run-time Error #57 "Device I/O"
    Involves the information being sent to the device.  Check all connections from the cutter to the computer.  It may also be necessary to restart both the computer and the cutter to clear this error.
  • Run-time Error #75 "Path/File Access Error"
    File location of path does not exist.  Check the spelling of the filename and path.